Northgate Sprinkler Repair Co.Denton, TX (940) 304-8736

Denton Watering Rules, Backflow Tests and Winter Prep

Denton's watering days, summer hours, yearly backflow test, $100 sprinkler tune-up rebate and freeze prep, with a link to each city and state source.

Fast Scheduling

Checked against city and state sources on October 22, 2026.

Denton's water comes from Lake Lewisville and Lake Ray Roberts, and a big share of it ends up on lawns. The city estimates that at least 40% of household water goes to irrigation, and about 70% in summer. That is why most of the rules below are about sprinklers.

These rules apply to homes on City of Denton water. If your bill comes from another provider, as it may in a neighboring town, follow that provider's rules instead.

Which days you can water

The city runs a twice-a-week irrigation schedule based on the last digit of your street number.

AddressWatering days
Even (ends in 0, 2, 4, 6 or 8, or no number)Tuesday and Saturday
Odd (ends in 1, 3, 5, 7 or 9)Wednesday and Sunday
Commercial and multifamilyMonday and Thursday

The city also says most lawns need only about one inch of water a week, counting rain. After a one-inch rain, you can skip the next week.

Summer hours: June 1 to September 30

From June 1 through September 30, running irrigation between 10 a.m. and 6 p.m. is prohibited. Water before 10 a.m. or after 6 p.m. instead.

Hand watering is exempt from the daytime ban, and so are soaker hoses used along a foundation. The city still asks residents to avoid watering foundations during those peak hours.

What counts as irrigation

  • On the schedule: automatic sprinkler systems and hose-end sprinklers.
  • Drip irrigation: not on the day schedule. Every system must still be installed and kept up so it does not cause runoff.
  • Foundation soaker hoses: not counted as irrigation.
  • Private wells: homes on their own well are not on the city schedule. The city asks them to follow their address days anyway, or post a sign saying they are on a well.
  • HOAs: they must comply with city, county and state watering directives too. If an HOA rule seems to conflict, the city's conservation staff offer help at [email protected].
  • Water waste: report it through Denton 311.

When drought stages apply

The schedule above is the normal one. Under the city's Drought Contingency Plan, tighter stages can be declared when supply is at risk. In 2026, Denton was in Stage 1 from August 19 to August 23 while a damaged basin at a treatment plant was repaired. Current status is posted at cityofdenton.com/water.

The yearly backflow test

A backflow prevention assembly is the set of valves that keeps water in your sprinkler lines from flowing back into the city's drinking water. Denton requires every one to be tested at least once a year. The city notes that homes with irrigation systems have at least one testable assembly on the irrigation line.

How it works:

  1. The letter. The city sends a compliance letter to remind you the test is due.
  2. The tester. Hire a tester from the city's list of registered backflow assembly testers. Testers must register with the city and hold a current backflow prevention assembly tester (BPAT) license. Since April 21, 2026 they file test reports through the city's online system.
  3. A failed test. The assembly must be repaired within the time frame in your letter, then retested.
  4. Skipping it. Missing the requirement can lead to non-compliance fees, criminal penalties or disconnection of water service.

Denton's updated backflow ordinance took effect on April 10, 2026. The city's summary says the changes do not affect typical new and existing homes inside city limits. They mainly cover new non-residential construction and fire lines.

State rules add one more test. An irrigation backflow assembly must be tested by a licensed tester whenever it is installed, repaired, replaced or relocated.

Permits and who can work on your system

  • Permits: in Denton, all new irrigation work, and any alteration to an existing system, needs a permit pulled by a licensed irrigator. Permitted jobs get a backflow inspection and a final inspection.
  • The city's checklist: the permit checklist says a double check valve is not accepted as the backflow device. It also asks for rain and freeze sensors on permitted systems, not mounted on fences.
  • State license: Texas requires a state license for anyone who sells, designs, installs, maintains, alters, repairs or services an irrigation system. A homeowner working on their own home doesn't need the license but still has to meet the state standards.
  • State standards for new systems:
    • a rain or moisture shut-off;
    • an isolation valve between the water meter and the backflow assembly;
    • no spray onto pavement, walls or fences.
  • Before you hire: look the irrigator up on the TCEQ license search.

Money back from the city

For homes on City of Denton water, the WaterWise program pays two rebates as credits on the water bill.

Sprinkler tune-up: 100% of the invoice, up to $100

  • The tune-up is done by a licensed irrigator you choose.
  • It can include cleaning heads, adjusting spray patterns, fixing leaks, flushing lines, and setting the controller to your watering days.
  • You can claim it twice in 12 months, with at least 3 months between invoices.

Smart controller: 100% up to $300, one time per property

  • The controller must be WaterSense-labeled, either weather-based or soil-moisture-based.
  • It must be connected to an in-ground system.
  • New-construction homes don't qualify.

To claim:

  • Apply online within 90 days of the work.
  • Include an itemized invoice, a photo of the controller showing your watering days, and the signed Irrigation Agreement.
  • The applicant must be the property owner, or have the owner's written consent.
  • Funding opens each fiscal year on October 1 and runs until it is used up.

The city's separate free irrigation evaluation program is suspended.

Getting your system through a freeze

For Dallas/Fort Worth, the National Weather Service lists November 22 as the average first freeze and March 12 as the average last. Texas A&M's School of Irrigation recommends four steps that protect most Texas systems from light to mild freezes:

  1. Turn off the controller.
  2. Shut off the irrigation water at the isolation valve near the meter or backflow assembly.
  3. Insulate any PVC pipe that is above ground.
  4. Drain above-ground parts such as the backflow assembly.

A&M notes that the compressed-air blowout method is mostly used in the northern U.S., where the ground freezes down to the buried pipe. It says most Texas systems are not designed for a blowout.

Turning the controller off saves money as well as pipe. Denton bases your wastewater charge on a percentage of the water you use from December through February, so sprinkler runs in those months can raise it.

Quick checklist

  • Controller set to your address days: Tuesday and Saturday, or Wednesday and Sunday.
  • No runs between 10 a.m. and 6 p.m. from June 1 to September 30.
  • Rain and freeze sensors working.
  • Backflow test done this year by a city-registered tester.
  • System off and drained before the first freeze.
  • Rebate application filed within 90 days of a tune-up.

If something on your system is broken rather than just mis-set, see sprinkler repair in Denton.

Official sources

Related Services

Reach us at (940) 304-8736, and you'll get a straight answer.

← Every service we offer in Denton

Northgate Sprinkler Repair Co.

Serving Denton, TX and surrounding areas.

Fast Scheduling

(940) 304-8736

Get a quote

Free quotes · No obligation.

Get a Quote